What should I do if my heat pump will not turn on?

Most no-start heat pump calls come down to a tripped breaker or disconnect, a thermostat/control problem, a failed capacitor or contactor, or a safety lockout shown by a code. The safest useful step is to check whether the indoor unit, outdoor unit, or both have lost power at the breaker panel and then note any thermostat or equipment error code before scheduling repair.

Schedule service soon

The system may still operate, but prompt service can restore comfort and limit additional wear.

Answer a few quick questions

Quick summary

Match what you notice to a safe next step

These observations can narrow the starting service, but they do not confirm which part has failed.

What you notice

Tripped breaker, blown fuse, or pulled outdoor disconnect

What it may point to

The heat pump is not getting power to the indoor air handler, the outdoor unit, or both, so it can be completely dead or only part of the system will try to start.

Safe next action

Check the thermostat display and the normal service switch

What you notice

Thermostat, low-voltage fuse, or control wiring fault

What it may point to

The equipment may have power available, but the 24-volt call for heating or cooling is not reaching the heat pump, so nothing starts when you change the setpoint.

Safe next action

Turn it off and describe the sound to a technician

What you notice

Failed run capacitor or contactor in the outdoor unit

What it may point to

If you hear a click or hum but the outdoor section does not come on, the unit is being told to start but a common electrical starting component has failed.

Safe next action

Reset it no more than once; stop if it trips again

What you notice

Control board lockout from a safety fault

What it may point to

A code on the thermostat or air handler often means the system detected a problem such as high pressure, low pressure, condensate overflow, or a defrost/control fault and is refusing to restart until diagnosed.

Safe next action

Record the exact code and consult the owner manual without opening panels

Safe things to check

  • Confirm the thermostat mode and setpoint
  • Inspect the air filter and replace it if visibly dirty
  • Make sure visible supply and return vents are open

Do not attempt

  • Do not handle, vent, or add refrigerant
  • Do not open sealed electrical or equipment panels
  • Do not bypass a safety switch or force repeated restarts

A few quick questions

Refine the best next step

Question 1 of 3

How much of the home is affected?
  1. 1How much of the home is affected?
  2. 2What is the system doing right now?
  3. 3When did this begin?

What this symptom can mean

Use the evidence you can observe

What this symptom usually means

A heat pump that will not turn on is different from one that runs poorly, blows the wrong temperature, or makes noise. This symptom means the startup sequence is failing at the beginning: either the equipment has no power, the controls are not sending a valid start signal, or a component is preventing the indoor or outdoor section from energizing. Whether the system is completely silent, gives one click, hums briefly, or shows a fault code helps narrow the fault much faster than room temperature alone.

What you can tell from what you see and hear

If both the thermostat and the equipment seem dead, a power supply problem is more likely, especially after a storm, electrical work, or a recent breaker trip. If the thermostat lights up normally but neither the indoor blower nor outdoor unit starts, the problem often shifts toward a low-voltage fuse, thermostat wiring, or a control board issue. If the indoor unit runs but the outdoor unit is silent, or you hear a click followed by nothing, the outdoor disconnect, contactor, or capacitor becomes more likely. If the display shows a code or alert, that usually means the system tried to protect itself and locked out rather than simply losing power.

How a technician separates the common causes

On a no-start call, the visit usually begins with confirming power at the breaker panel, the service disconnect, and the air handler or furnace control compartment. The technician then checks whether the thermostat is actually sending a 24-volt call and whether any control fuse is open. If the unit clicks or hums, electrical testing often moves to the contactor, capacitor, blower motor, outdoor fan motor, and compressor circuit. When a fault code is present, the code is only the starting point; the real job is finding what triggered the lockout and whether it was a one-time event or an active failure.

What usually gets repaired on this kind of call

Repairs for a heat pump that will not start are often electrical or control related rather than airflow related. Common fixes include replacing a failed dual-run capacitor, contactor, low-voltage fuse, thermostat, transformer, or a damaged control wire, as well as correcting a loose connection at the disconnect or breaker. More involved repairs include blower motor replacement, control board replacement, or diagnosing a compressor that is locked, grounded, or drawing excessive amperage. If a safety switch or fault code is involved, the underlying cause still has to be corrected or the shutdown will return.

What affects repair cost

Cost depends mainly on which section failed and whether the fault is a simple power/control issue or a major motor/compressor problem. Typical 2025-2026 U.S. repair estimates are roughly $150-$400 for a capacitor, contactor, fuse, or minor electrical repair, about $200-$650 for thermostat, transformer, or basic control repairs, around $600-$1,500+ for blower motor or control board work, and often $1,500-$3,500+ if the compressor or major outdoor components are involved. Final price also changes with system age, brand-specific parts, after-hours timing, and whether repeated breaker trips caused additional damage.

If you noticed a breaker trip, code, click, or short hum before shutdown, mention that when arranging service because it helps the contractor bring the right test equipment and likely replacement parts. HVAC Rescue is a referral service, not the company performing the repair, so pricing, arrival times, and parts availability depend on the independent contractor you choose.

When to turn the system off

  • Stop if you smell gas, see smoke or sparks, or hear a carbon-monoxide alarm
  • Stop if water reaches powered equipment or a breaker trips again
  • Stop if loud grinding, booming, or heavy ice appears

When to call for help

  • Call when the symptom continues after the safe checks
  • Call promptly when comfort is lost for the whole home
  • Describe when it started and any water, ice, noise, odor, alert, or breaker activity

Cost guidance

What could this cost to fix?

Price depends on the actual cause, equipment, access, and local labor. Compare the national ranges in the HVAC Repair Cost guide, or check service availability for your system.

Find local help for Heat Pump Repair

We will keep this problem and recommended service selected while you answer a few quick availability questions.

Browse HVAC help by state
Check Availability

Frequently asked questions

Heat pump will not turn on: common questions

Why does my heat pump click but not start?
A click usually means the thermostat or control board is calling for operation and a relay or contactor is trying to engage. Common reasons it still does not start are a failed capacitor, a bad contactor, low incoming voltage, or a compressor or fan motor that cannot get moving. If it clicks repeatedly every few seconds or minutes, the system may be trying and failing to restart.
If the breaker for my heat pump is tripped, can I just reset it once?
Many homeowners reset a tripped breaker once to see whether the unit was hit by a temporary power event, but if it trips again right away or during the next call for heating or cooling, stop there and schedule service. Repeated trips point to a short, over-amping motor, compressor issue, or failing electrical component. A breaker that will not stay on is not a thermostat problem until power issues are ruled out.
What does it mean if my thermostat has power but the heat pump will not come on?
That usually means house power is present, but the 24-volt control circuit or equipment side is not completing the startup command. A blown low-voltage fuse, failed transformer, broken thermostat wire, safety lockout, or failed control board are common possibilities. If the thermostat shows a specific error code, write it down exactly because the wording matters during diagnosis.
How long does it take to diagnose a heat pump that will not turn on?
Straightforward no-power or bad-capacitor calls are often diagnosed within 30 to 60 minutes. If the system has intermittent lockouts, multiple control boards, or a compressor that is hard-starting or tripping protection, testing can take longer because the technician may need to trace voltage step by step and watch how the unit behaves during a restart attempt.
Is a heat pump not turning on usually expensive to fix?
Not always. Many no-start calls end up being a capacitor, contactor, fuse, thermostat, or other control issue that falls in the low hundreds rather than the thousands. Costs rise when the failure involves a blower motor, control board, or especially the compressor, and older systems can become harder to repair if parts are delayed or obsolete.