What should I do if my heat pump is not heating?

Most no-heat heat pump calls come down to a thermostat setup or control problem, a low-refrigerant or compressor issue that leaves the unit moving air without adding heat, a stuck reversing valve, or an outdoor unit/defrost fault. The most useful safe step is to set the thermostat to HEAT and raise it 3-5 degrees, then note whether the outdoor unit runs, whether air feels lukewarm or cold, and whether only one zone is affected before scheduling service.

Schedule service soon

The system may still operate, but prompt service can restore comfort and limit additional wear.

Answer a few quick questions

Quick summary

Match what you notice to a safe next step

These observations can narrow the starting service, but they do not confirm which part has failed.

What you notice

Thermostat or control board not actually calling for heat

What it may point to

The blower can still run while the heat pump never switches into heating mode, so the house stays cold even though air is coming from the vents.

Safe next action

Confirm the thermostat mode and note whether the outdoor unit is running

What you notice

Low refrigerant charge or a compressor that is not pumping properly

What it may point to

The system is circulating air but cannot move enough heat indoors, which often feels like cool or barely warm airflow and longer-than-normal run times.

Safe next action

Inspect the filter and make sure visible vents are open

What you notice

Reversing valve stuck in cooling or stuck between modes

What it may point to

The heat pump may run, but it is not directing refrigerant through the heating cycle, so the air at the vents can feel neutral or even cool.

Safe next action

Turn the system off and arrange professional service

What you notice

Outdoor unit problem such as a failed fan motor, contactor, capacitor, or defrost control fault

What it may point to

If the outdoor section cannot run correctly in winter, the system may blow unheated air inside, ice up, or struggle until backup heat takes over poorly or not at all.

Safe next action

Compare airflow at nearby vents and note the affected rooms

Safe things to check

  • Confirm the thermostat mode and setpoint
  • Inspect the air filter and replace it if visibly dirty
  • Make sure visible supply and return vents are open

Do not attempt

  • Do not handle, vent, or add refrigerant
  • Do not open sealed electrical or equipment panels
  • Do not bypass a safety switch or force repeated restarts

A few quick questions

Refine the best next step

Question 1 of 3

How much of the home is affected?
  1. 1How much of the home is affected?
  2. 2What is the system doing right now?
  3. 3When did this begin?

What this symptom can mean

Use the evidence you can observe

What this symptom usually means

A heat pump that is not heating is different from a noisy unit, a frozen outdoor unit, or a water leak. In this case, the key clue is that the system runs but the home temperature does not rise as it should. That usually means the equipment is moving air without completing the heating cycle correctly, or it is producing some heat but not enough to overcome the home's heat loss.

What you can tell from the way it behaves

Normal airflow with little or no warmth often points toward a refrigerant, compressor, reversing valve, or control problem rather than a simple duct restriction. Weak airflow with poor heating shifts suspicion toward an indoor blower issue, a collapsed duct, or a zone damper problem. If only one room or one zone is cold while the rest of the house heats normally, the heat pump itself may be fine and the fault may be in the zone control, damper motor, or branch duct serving that area.

If you also see ice on the outdoor unit, hear the system run for long stretches, or notice the air gets colder during heating calls, the outdoor section may not be defrosting correctly or may not be moving refrigerant as it should. If there is a new buzzing, humming, or hard-start sound from outdoors and heat output dropped at the same time, technicians often find a failing capacitor, contactor, fan motor, or compressor-related issue. Water near the air handler during a heating complaint can happen during defrost or from a secondary drain issue, but it does not by itself explain why the system is not adding heat.

What a technician usually checks on a no-heat heat pump call

A service visit for this symptom typically starts with confirming that the thermostat and control board are sending a true heating call, then checking temperature rise, refrigerant pressures, compressor operation, outdoor fan operation, and whether the reversing valve is shifting into heat. On systems with auxiliary or emergency heat, the technician will also verify whether backup heat is energizing when it should and whether the heat pump is carrying the load before backup is needed. If one zone is cold, they may test damper operation and airflow room by room instead of treating it like a whole-system failure.

What affects repair cost

Cost depends heavily on whether the problem is a control issue, an airflow problem, or a sealed-system problem. Thermostat, relay, capacitor, or contactor repairs are often on the lower end, while blower motor, outdoor fan motor, defrost board, or reversing valve repairs are usually higher. Refrigerant leak diagnosis, leak repair, and recharge can become one of the more expensive outcomes because it involves sealed-system work and refrigerant. Typical 2025-2026 US repair ranges are roughly $150-$450 for common electrical parts, $400-$1,200 for many motor or board repairs, and about $800-$2,500+ when leak repair, reversing valve work, or major refrigerant-system repairs are needed.

If the unit is older, uses an expensive legacy refrigerant, or has both poor heating performance and compressor trouble, replacement may come up during the visit even though the service call started as a no-heat complaint. That is especially common when the system can still move air but cannot produce enough heat to hold temperature in cold weather.

When to turn the system off

  • Stop if you smell gas, see smoke or sparks, or hear a carbon-monoxide alarm
  • Stop if water reaches powered equipment or a breaker trips again
  • Stop if loud grinding, booming, or heavy ice appears

When to call for help

  • Call when the symptom continues after the safe checks
  • Call promptly when comfort is lost for the whole home
  • Describe when it started and any water, ice, noise, odor, alert, or breaker activity

Cost guidance

What could this cost to fix?

Price depends on the actual cause, equipment, access, and local labor. Compare the national ranges in the HVAC Repair Cost guide, or check service availability for your system.

Find local help for Heat Pump Repair

We will keep this problem and recommended service selected while you answer a few quick availability questions.

Browse HVAC help by state
Check Availability

Frequently asked questions

Heat pump is not heating: common questions

Why is my heat pump blowing air but the house still feels cold?
A heat pump can keep the indoor blower running even when the outdoor unit is not producing much heat. Common reasons are a bad heating call from the controls, low refrigerant, a compressor problem, or a reversing valve that is not switching fully into heat. If the air feels room-temperature instead of distinctly warm after 10-15 minutes of operation, schedule service soon.
Why is my heat pump not heating one room or one zone?
When only one room or zone is affected, the problem is often downstream of the heat pump itself. Technicians commonly find a stuck zone damper, failed zone actuator, disconnected or crushed branch duct, or an airflow balance problem. That kind of diagnosis is usually faster than sealed-system testing, but access to dampers and ducts can affect labor time.
Is it normal for heat pump air to feel less hot than a furnace?
Yes. Supply air from a heat pump in heating mode often lands around 85-100°F, while a gas furnace can deliver roughly 120-140°F air, so a heat pump can feel milder at the vents even when it is working properly. The real test is whether the room temperature rises steadily over 30-60 minutes during a heating call.
Why did my heat pump stop heating after the weather got much colder?
Colder outdoor temperatures reduce how much heat a heat pump can pull from the air, so existing problems become more obvious during a cold snap. A weak compressor, low refrigerant charge, outdoor fan problem, or defrost issue may let the system seem acceptable in mild weather but fail to keep up when outdoor temperatures drop. If indoor temperature falls several degrees below the thermostat setting and does not recover, the system needs diagnosis.
Can a refrigerant leak cause my heat pump to run all day without warming the house?
Yes. Low refrigerant often causes long run times, poor heat output, and air that feels cool or only slightly warm. Sealed-system diagnosis and refrigerant work require a qualified technician, and published 2025-2026 repair costs commonly range from several hundred dollars for basic leak detection to well over $1,500 when leak repair and recharge are both needed.