Quick summary
Match what you notice to a safe next step
These observations can narrow the starting service, but they do not confirm which part has failed.
What you notice
Outdoor unit electrical failure such as a bad capacitor, contactor, or fan motor
What it may point to
The indoor part can still blow room-temperature air while the outside section fails to reject heat, so the house stays warm even though the system sounds like it is running.
Safe next action
Confirm the thermostat mode and note whether the outdoor unit is running
What you notice
Low refrigerant from a leak
What it may point to
The heat pump cannot absorb enough heat indoors, so supply air feels only slightly cool or not cool at all, and performance usually gets worse over days or weeks.
Safe next action
Inspect the filter and make sure visible vents are open
What you notice
Evaporator coil freezing
What it may point to
Ice on the indoor coil blocks airflow and heat transfer, so cooling drops sharply and you may notice weak airflow, water after thawing, or frost on refrigerant lines.
Safe next action
Turn the system off and arrange professional service
What you notice
Indoor blower problem or duct restriction
What it may point to
If the system cools some rooms but not others, or airflow is weak at many vents, the equipment may be producing cooling but not delivering it through the house properly.
Safe next action
Compare airflow at nearby vents and note the affected rooms
Safe things to check
- Confirm the thermostat mode and setpoint
- Inspect the air filter and replace it if visibly dirty
- Make sure visible supply and return vents are open
Do not attempt
- Do not handle, vent, or add refrigerant
- Do not open sealed electrical or equipment panels
- Do not bypass a safety switch or force repeated restarts
A few quick questions
Refine the best next step
Question 1 of 3
- 1How much of the home is affected?
- 2What is the system doing right now?
- 3When did this begin?
What this symptom can mean
Use the evidence you can observe
What this symptom usually means
When a heat pump is not cooling, the key issue is that the refrigeration cycle is running incorrectly or not running fully. The thermostat may call for cooling and the indoor fan may still move air, but if the outdoor section is not removing heat, the air coming from the vents will feel neutral, slightly cool, or warm instead of clearly colder than the room.
What your observations can tell you
Normal airflow with poor cooling points first to the outdoor unit, refrigerant charge, reversing valve, or compressor operation. Weak airflow points more toward a frozen indoor coil, blower problem, or duct issue. If you see ice on the refrigerant line or air handler, cooling often falls off before airflow gets very weak; if you find water later, that is commonly meltwater after the ice begins to thaw, not a separate leak problem.
A new noise helps narrow it down. Rapid clicking outside can mean a contactor or start component problem, a loud hum without strong cooling can point to compressor starting trouble, and a blower that sounds normal indoors while the outdoor unit stays unusually quiet often means the outdoor section is not actually operating. If only one room or zone stays hot, the issue is less likely to be the refrigerant circuit and more likely to involve zone dampers, branch duct leakage, or airflow balancing.
What to do before service
If you see ice, switch the thermostat off and give the system 30 to 60 minutes to start thawing before service, because a frozen coil can hide the original fault. If there is no ice and the system runs but does not cool, avoid repeatedly lowering the thermostat far below room temperature; that usually does not fix the problem and can add stress if the compressor is already struggling. Refrigerant and electrical diagnosis inside the equipment should be left to a qualified technician.
What a service visit usually includes
A technician typically confirms the temperature split across the indoor coil, checks whether the outdoor fan and compressor are both operating, tests capacitors and contactors, measures refrigerant pressures and line temperatures, inspects for ice or airflow restriction, and verifies whether the reversing valve is shifting into cooling mode. If one room or zone is the problem, they may also inspect dampers, duct connections, and static pressure rather than focusing only on the heat pump cabinet.
What affects repair cost
Cost depends on whether the fix is an electrical component, an airflow repair, or a sealed-system problem. Typical 2025–2026 U.S. repair ranges are roughly $150–$450 for a capacitor or contactor, $300–$900 for a blower motor or control issue, $200–$1,200 for refrigerant leak testing and recharge depending on refrigerant type and leak location, and $1,500–$4,000 or more for major compressor or coil repairs. Zoning and duct repairs vary widely because access to dampers, attics, and concealed runs often matters as much as the part itself.
When to turn the system off
- Stop if you smell gas, see smoke or sparks, or hear a carbon-monoxide alarm
- Stop if water reaches powered equipment or a breaker trips again
- Stop if loud grinding, booming, or heavy ice appears
When to call for help
- Call when the symptom continues after the safe checks
- Call promptly when comfort is lost for the whole home
- Describe when it started and any water, ice, noise, odor, alert, or breaker activity
Cost guidance
What could this cost to fix?
Price depends on the actual cause, equipment, access, and local labor. Compare the national ranges in the HVAC Repair Cost guide, or check service availability for your system.
Find local help for Heat Pump Repair
We will keep this problem and recommended service selected while you answer a few quick availability questions.
Browse HVAC help by stateFrequently asked questions
Heat pump is not cooling: common questions
Why is my heat pump running but the air coming out is not cold?
If my heat pump is iced up, will it start cooling again after it thaws?
Why is my heat pump not cooling one room or one zone only?
Can low refrigerant make a heat pump cool a little, but not enough?
How long should a heat pump take to cool the house?