What should I do if my boiler is not heating?

Most no-heat boiler calls come down to a thermostat or zone control not actually calling for heat, low boiler water pressure preventing circulation, a failed circulator pump, or an ignition/burner control problem that keeps the boiler from firing. The most useful safe step is to raise the thermostat several degrees and check whether the boiler pressure and any zone valves change when heat is requested, then schedule boiler service soon.

Schedule service soon

The system may still operate, but prompt service can restore comfort and limit additional wear.

Answer a few quick questions

Quick summary

Match what you notice to a safe next step

These observations can narrow the starting service, but they do not confirm which part has failed.

What you notice

Thermostat, zone valve, or relay not calling for heat

What it may point to

The boiler itself may be capable of heating, but the signal to start a heating cycle is not reaching the correct zone, so the house stays cold or only one area does.

Safe next action

Confirm the thermostat mode and note whether the outdoor unit is running

What you notice

Low system pressure or insufficient water in the boiler loop

What it may point to

Hot water cannot circulate properly through radiators, baseboards, or radiant loops, so the boiler may run briefly or not deliver usable heat to the home.

Safe next action

Inspect the filter and make sure visible vents are open

What you notice

Failed circulator pump or stuck flow-check component

What it may point to

The burner can produce heat, but that heat is not being moved through the system, which often feels like the boiler is running while rooms never warm up.

Safe next action

Turn the system off and arrange professional service

What you notice

Ignition, flame-sensing, or burner control failure

What it may point to

The thermostat can be asking for heat, but the boiler never establishes or maintains flame, so no hot water is created for the heating system.

Safe next action

Compare airflow at nearby vents and note the affected rooms

Safe things to check

  • Record the pressure reading and any displayed code
  • Confirm the thermostat is calling for heat
  • Look for visible water without touching internal boiler parts

Do not attempt

  • Do not adjust gas valves, burners, ignition parts, or venting
  • Do not open sealed electrical or equipment panels
  • Do not bypass a safety switch or force repeated restarts
  • Do not cap a relief valve or work on internal boiler controls

A few quick questions

Refine the best next step

Question 1 of 3

How much of the home is affected?
  1. 1How much of the home is affected?
  2. 2What is the system doing right now?
  3. 3When did this begin?

What this symptom can mean

Use the evidence you can observe

What this symptom usually means on a boiler system

When a boiler is not heating, the problem is usually somewhere in the heat-making or heat-moving path: the thermostat or zone control may not be asking for heat, the boiler may not be firing, or the hot water may not be circulating through the home. That is different from a leak, a pressure-only complaint, or a noise-only complaint because the defining symptom here is simple: the living space stays cold even though the system should be producing heat.

What to look for before the service visit

If the whole house is cold, watch what happens after you raise the thermostat 3 to 5 degrees. A healthy system should usually show some response within a few minutes: a zone valve moves, a circulator starts, or the boiler begins a firing sequence. If nothing changes at all, the issue is often the thermostat circuit, transformer, relay, or zone control. If the boiler starts but radiators or baseboards stay cool, circulation or water-pressure problems move higher on the list.

If only one room or one zone is cold, the problem is less likely to be the main boiler and more likely to be a stuck zone valve, air in that loop, a failed circulator assigned to that zone, or a closed balancing valve left from prior service. In homes with baseboard or radiators, one cold section next to several warm ones usually points to flow trouble rather than a burner problem.

Boiler pressure matters because hydronic heat depends on water volume and movement. Many residential systems run around 12 to 20 psi when cool to moderately warm. If the gauge is notably below normal, the boiler may lock out, short-cycle, or fail to push heat to upper floors. If the pressure looks normal but the boiler cabinet is warm and supply piping is hot while rooms remain cold, a circulator or zone-flow issue becomes more likely.

How technicians usually diagnose a no-heat boiler call

A technician will typically verify the call for heat from the thermostat and zone controls, check boiler pressure and temperature, confirm whether the circulator is running, and test the ignition and safety sequence. On zoned systems, they may check whether each valve opens fully and whether hot water is actually moving through the branch that serves the cold area. If air is suspected, they may purge the loop and confirm the feed and expansion components are working correctly.

What usually affects repair cost

Cost depends on which part of the heating chain has failed. A thermostat, relay, or zone valve head is often less costly than replacing a circulator pump, control board, or ignition assembly. Typical 2025-2026 U.S. repair ranges are roughly $150-$400 for thermostat or control-call issues, $250-$700 for zone valve or air-purge work, $500-$1,200 for many circulator pump replacements, and $300-$1,500+ for ignition or boiler control repairs, with higher totals possible on older or high-end systems. Access to piping, number of zones, boiler type, and whether parts are OEM-specific also change the price.

When to turn the system off

  • Stop if you smell gas, see smoke or sparks, or hear a carbon-monoxide alarm
  • Stop if water reaches powered equipment or a breaker trips again
  • Stop if loud grinding, booming, or heavy ice appears

When to call for help

  • Call when the symptom continues after the safe checks
  • Call promptly when comfort is lost for the whole home
  • Describe when it started and any water, ice, noise, odor, alert, or breaker activity

Cost guidance

What could this cost to fix?

Price depends on the actual cause, equipment, access, and local labor. Compare the national ranges in the HVAC Repair Cost guide, or check service availability for your system.

Find local help for Boiler Repair

We will keep this problem and recommended service selected while you answer a few quick availability questions.

Browse HVAC help by state
Check Availability

Frequently asked questions

Boiler is not heating: common questions

Why is my boiler running but the house is still cold?
That usually means the boiler is generating some heat but the system is not moving it where it needs to go. Common reasons are a failed circulator pump, a stuck zone valve, trapped air, or low water pressure. If the boiler jacket is warm and nearby piping heats up but rooms do not, circulation is often the issue.
Why is only one zone or one room not heating on a boiler system?
A single cold zone usually points to a problem in that zone's valve, circulator, or piping loop rather than the entire boiler. Air trapped in that branch can also stop hot water from reaching the room. Technicians often isolate the zone, test the valve motor or end switch, and confirm flow through that loop.
What boiler pressure should I see when the heat is not working?
Many residential boilers sit around 12 to 15 psi when cool and often rise into the mid-teens as they warm up, though the correct range depends on the home and system design. If the gauge is far below normal, especially under about 10 psi in many two-story homes, heat delivery can suffer or the boiler can lock out. Pressure that is normal does not rule out a bad circulator or zone control.
Can I still have no heat if the pilot or burner seems to come on?
Yes. On hydronic systems, making heat and delivering heat are two separate steps. The burner can fire normally while a dead circulator, closed zone valve, or air-bound loop prevents that heat from reaching radiators or baseboards.
How long does a boiler no-heat diagnosis usually take?
Basic diagnosis is often completed in 30 to 90 minutes, depending on the number of zones and how accessible the boiler and piping are. If the issue involves intermittent controls, air in multiple loops, or older replacement parts, the visit can take longer. Repair timing also depends on whether the needed part is stocked locally.